| Topdek : Product Data | ||||||
|
Topdek is a single-ply Insulated roof deck system. Topdek is factory pre-engineered single fix membrane deck system for applications on flat, pitched or curved roofs. Insulation Core
|
|
Panel Thickness |
U value W/m²K |
|
80 |
0.25 |
|
100 |
0.19 |
U - Thermal transmittance W/m²K
l - Long-term Thermal conductivity W/mK
Insulation Continuity
Topdek is factory pre-engineered to guarantee total insulation continuity.
Airtightness
Sustainability and Energy Efficiency
Topdek provides Parts L2A, L2B & J thermal performance, insulation
continuity and airtightness certainty, allowing downsizing of M&E plant,
which in turn reduces energy usage and carbon dioxide (CO2) emissions
by up to 40% per annum, over the buildings lifetime.
Acoustics
Topdek panels have a single figure weighted sound reduction Rw = 23dB.
Sound Reduction Index (SRI)
|
Frequency Hz |
SRI dB |
|
125 |
17.9 |
|
250 |
18.1 |
|
500 |
17.4 |
|
1k |
23.2 |
|
2k |
30.4 |
|
4k |
40.3 |
Biological
Topdek panels are immune to attack from mould, fungi, mildew and vermin.
No urea formaldehyde is used in the construction, and the panels are non-deleterious.
Specification
NBS specifications are available from Ward Technical Services Department
on:
Telephone: 01944 712220
Email: cladding.technical@wards.co.uk
Topdek is manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with ISO9002 and EN29002 standards.
Site Installation
Ward will provide product warranties and guarantees on an individual project basis.
Topdek panels are stacked weather sheet to weather sheet
(to minimise pack height). The top, bottom, sides and ends are protected
with foam and timber packing and the entire pack is protective wrapped.
The number of panels in each pack depends on panel thickness, as shown
in the table. Typical pack height is 1100mm.
|
Panel Core |
No. Panels/ |
|
80 |
8 |
|
100 |
6 |
All deliveries are by road transport (unless indicated otherwise) to project site. Off loading is the responsibility of the cladding contractor or installer.
Sea Freight
Ward provide a sea freight despatch service.
Site assembly methods and instructions are available from the Ward Technical Services Department.
Training for contractors is necessary and is available from Ward.
Flat and Pitched Roofs
Topdek can be used on building applications with a minimum roof pitch
of 1:80 (0.72°) to avoid ponding.
Curved Roofs
For curved and inverted curve roofs with radi greater than 70 metres.
Dimensions

End Lap
Side Lap

|
A - core thickness (mm) |
80 |
100 |
|
B - overall dimension (mm) |
118 |
138 |
|
Weight kg/m² 1.5mm single ply membrane |
12.55 |
13.39 |
|
Cut to Length |
-0.05% |
+0.1% |
|
Cover Width |
-0mm |
+3mm |
|
Thickness |
-2mm |
+2mm |
|
End Square |
-3mm |
+3mm |
External and Internal Facings
Internal Deck Substrate Specifications
Internal Coating Specifications
Available Lengths
Standard lengths 1.5 to 16 metres. Panels to 8 metres may be man handled,
above this length consideration must be given to lifting methods. Panels
less than 1.5m long can be supplied but are subject to additional charge.